Oracle7 Server Messages
 
 
 
 
 
04000-04019: Command Parameters 
This section lists some of the messages generated when inconsistent values are used in a command. 
	ORA-04000	the sum of PCTUSED and PCTFREE cannot exceed 100 
| Cause: | The sum of the PCTUSED and PCTFREE values specified for a cluster or table exceeds 100.  | |
| Action: | Create the table or cluster specifying values for PCTUSED and PCTFREE. The sum of these values cannot exceed 100.  | |
	ORA-04001	sequence parameter str must be an integer 
| Cause: | The specified sequence parameter was not an integer.  | |
| Action: | Create the sequence, giving the specified parameter an integer value.  | |
	ORA-04002	INCREMENT must be a non-zero integer 
| Cause: | A sequence increment was specified as zero.  | |
| Action: | Specify the increment as a non-zero value.  | |
	ORA-04003	sequence parameter num exceeds the maximum size allowed num digits
| Cause: | The specified sequence parameter has too many digits.  | |
| Action: | Specify the parameter with the allowed number of digits and try again.  | |
	ORA-04004	MINVALUE must be less than MAXVALUE 
| Cause: | MINVALUE was specified to be greater than or equal to MAXVALUE.  | |
| Action: | Specify a MINVALUE that is less than MAXVALUE and try again.  | |
	ORA-04005	INCREMENT must be less than MAXVALUE minus MINVALUE 
| Cause: | INCREMENT was specified as equal to or greater than MAXVALUE minus MINVALUE. This is not permitted.  | |
| Action: | Specify INCREMENT as less than MAXVALUE minus MINVALUE and
try again.  | |
	ORA-04006	START WITH cannot be less than MINVALUE 
| Cause: | The given starting value is less than MINVALUE.  | |
| Action: | Check that the starting value is not less than MINVALUE and try again.  | |
	ORA-04007	MINVALUE cannot be made to exceed the current value 
| Cause: | The given MINVALUE is greater than the current value.  | |
| Action: | Check that MINVALUE is not greater than the current value and try again.  | |
	ORA-04008	START WITH cannot be more than MAXVALUE 
| Cause: | The starting value is larger than MAXVALUE.  | |
| Action: | Check that the starting value is less than MAXVALUE and try again.  | |
	ORA-04009	MAXVALUE cannot be made to be less than the current value 
| Cause: | The current value exceeds the given MAXVALUE.  | |
| Action: | Check that the new MAXVALUE is larger than the current value and try again.  | |
	ORA-04010	the number of values to CACHE must be greater than 1 
| Cause: | The value specified in the CACHE clause of a CREATE SEQUENCE statement is 1. The default value is 20. | |
| Action: | Specify NOCACHE or a value greater than 1 and try again.  | |
	ORA-04011	sequence name must range between num and num
| Cause: | The value specified for one of the sequence parameters exceeds limits. | |
| Action: | Specify a parameter within these limits. | |
	ORA-04012	object is not a sequence 
| Cause: | The object specified cannot have sequence operations performed on it.  | |
| Action: | Re-enter the statement, making sure to spell the sequence name correctly.  | |
	ORA-04013	number to CACHE must be less than one cycle 
| Cause: | The number to CACHE specified in a CREATE SEQUENCE statement exceeds the number of values in a cycle.  | |
| Action: | Enlarge the cycle or cache fewer values, and try again.  | |
	ORA-04014	descending sequences that CYCLE must specify MIN VALUE 
| Cause: | A value was not specified in the CREATE SEQUENCE statement. Sequences that cycle must specify a value at which to begin again.  | |
| Action: | Re-create the sequence, specifying the value at which it is to begin.  | |
	ORA-04015	ascending sequences that CYCLE must specify MAX VALUE 
| Cause: | A value was not specified in the CREATE SEQUENCE statement. Sequences that cycle must specify a value at which to begin again.  | |
| Action: | Recreate the sequence, specifying the value at which it is to begin.  | |
	ORA-04016	sequence name no longer exists
| Cause: | Sequence was dropped while processing its next value. | |
| Action: | Recreate the sequence | |